A01-10-D06_6X6X7


A01-10-D06_6X6X7

Product Tags

A01-10-D06

1.General specification

1.1 Scope

This specification covers the requirements for single key switches which have no key top(TACT SWITCHES:MECHANICAL CONTACT).

1.2 Operating Temperature Range

  -20 to +70 ℃ , (normal humidity,normal press.)

1.3 Storage Temperature Range

  -25 to +85 ℃ , (normal humidity,normal press.)

1.4Test Conditions

Tests and measurements shall be made in the following standard conditions unless otherwise specified:

Normal temperature (temperature 5 to 35 ℃)

Normal humidity (relative humidity 45 to 85% )  Normal pressure (pressure 860 to 1060 mbars)

2.TYPE OF ACTUATION

Tactile feedback

3.CONTACT ARRANGEMENT

1  1  1 poles 1 throws

(Details of contact arrangement are given in the assembly drawings.)

4.MAXIMUM RATINGS DC 12 V 50 mA

5.Appearance and structure

5.1Appearance:It should no obvious shrinkin 、upset metal、Scrape、plating path well-distributed and no coming off.

5.2Size:Making (drawing attached)  2

6. General specification
6.1Electrical properties

Item

Test Condition Requirements
6.1.1

Contact Resistance

 1 (kHz).Applying static load twice the actuating force to the center of the stem, measurements shall be made with a 1 kHz small-current contact resistance meter. 100 mΩ≤ 100
6.1.2 Insulation Resistance

DC 100 V/

Measurements shall be made following application of DC 100 V potential between terminals and between individual terminals and frame for one minute.

100 MΩ≥ 100
6.1.3

Dielectric withstanding voltage

,AC 250 V (50HZ-60HZ)

AC 250 V (50Hz or 60Hz) shall be applied between terminals and between individual terminals and frame for one minute.

There shall be no breakdown
6.1.4 Bounce ( 3 - 4 ),Lightly striking the center of the stem at a rate encountered in normal use( 3 to 4 operations per sec),Bounce shall be tested when"ON" and "OFF"cdscs 10 mS

6.2  Mechanical properties

Item

Test Condition Requirements
6.2.1 Actuating Force Place the switch such that the direction of switch operation is vertical and then gradually increase the load applied to the center of the stem,

the maximum load required for the stem to come to a stop shall be measured

250 ± 50 gf
6.2.2 Travel Place the switch such that the direction of switch operation is vertical and then apply a static load twice the actuating force to

the center of the stem,the travel distance for the stem to come to a stop shall be measured

250 gf: 0.25 ± 0.05 mm
6.2.3 Return Force The sample switch is installed such that

the direction of switch operation is vertical and,upon depression of the stem in

its center the whole travel distance,the force of the stem to return to its free position shall be measured

250 gf: 80 gf min
6.2.4 Static Strength 1KG , 60

Placing the switch such that the direction

of switch operation is vertical,a static load of 3 kgf shall be applied in the direction of stem operation for a period of 60 seconds

There shall be

no sign of damage mechanically and electrically

6.3  Service Durability

Item

Test Condition Requirements
6.3.1 Operating Life Measurements shall be made following the test set forth below:

(1) 1.5No load condition

(2): 60 ~ 120 /

Rate of operation: 60 to 120 operations per minute  

(3):10,5Cycles of operation:Stainless steel 100,000 cycles,

Silver coated copper 50,000 cycles

Contact resistance:

  100 mΩ Max. Insulation resistance:

  100 MΩ Min.

Actuating force:

± 30% 

+ 30% or- 30% of initial force  Item 6.2.2

6.3.2 Moisture Resistance  1

Following the test set forth below the sample shall be left in normal temperature and humidity conditions for one hour

before measurements are made.

(1)  Temperature: 40  ±  2  ℃ (2) Relative humidity: 90 to 95% (3)  Time: 96  hours

Water drops shall be removed.

Contact resistance:

  100 mΩ Max. Insulation resistance:

  100 MΩ Min   Item 6.1.3、6.1.4

  Item 6.2.1~6.2.3

6.3.3 Low Temperature Resistance 1

Following the test set forth below the sample shall be left in normal temperature and humidity conditions for one hour

before measurements are made

(1)  Temperature: -20 ± 2 ℃ (2)  Time: 96  hours

Water drops shall be removed.

Contact resistance:

  100 mΩ Max. Insulation resistance:

  100 MΩ Min   Item 6.1.3、6.1.4

  Item 6.2.1~6.2.3

Item

Test Condition Requirements

6.3.4

Heat Resistance

 1 Following the test set forth below the sample shall be left in normal temperature and humidity conditions for one hourbefore measurements are made(1)  Temperature: 70 ± 2 ℃ (2)  Time: 96  hours

Contact resistance:

  100 mΩ Max. Insulation resistance:

  100 MΩ Min   Item 6.1.3、6.1.4

 Item

6.2.1~6.2.3

6.3.5

Change of

Temperature

1 Following ten cycles of high temperature test. The Sample shall be Placed in Normal temperature and humidity Conditions for one hour before measurements are made. Duringthis test, water drops shall be removed

cdscds

Contact resistance:  100 mΩ Max.Insulationresistance:  100 MΩ MinItem6.1.3、6.1.4

Item

6.2.1~6.2.3

6.3.6 Salt Spray Test The salt spray test shall be conducted at the following conditions:(1)  Density:( 5 ± 1 )%Nacl() (2)   Temperature: 35 ± 2  (3)  Time: 6  hours No yellowing and rusting of metal parts

Item

Test Condition Requirements

 Item 6.1  Item 6.2.1、6.2.2

6.3.7  Vibration Resistance Measurements shall be made following the test
set forth below:
(1) Range of oscillation: 10 to 55 Hz (2) Amplitude: - 1.5 mm(pk-to-pk: 1.5 mm) (3) Cycle of sweep: 10 - 55 - 10 Hz(in one minute, approx.)
(4) Mode of sweep:
(Logarithmically sweep or uniform sweep.)
(5) Direction of oscillation: 3 ,(Three
mutually perpendicular directions, including
the direction of stem travel.)
(6) 2 . 6 ( 2 hours each,for a total of 6 hours.)
Measurements shall be made following the test set
forth below:
(1)  Acceleration: 80 g Cycles of test:  3 , 6  18 ( 3 cycles each in 6 directions, for a total of 18 cycles)

6.3.8

  Impact Shock Resistance

huhih

 Item 6.1  Item 6.2.1、6.2.2

7. Welding conditions

Item

Recommended conditions
 

 

 

7.1

 

 

 

 

Hand soldering

 

 

 
(1):≤ 350
(2):≤ 3 S (3):≤ 60 W

Please practice according to bellow conditions:

(1)Soldering temperature :≤ 350 ℃

(2)Continuous soldering time:≤ 3 S
(3)Capacity of soldering iron:≤ 60 W
Available for Snap-in Type and Radial Type
Items

Condition

Flux buit-up Mounting surface shoud not be coated with flax
7.2 Condiftons for

Auto-dip

 

 

 

 

 

Preheating temperature

100℃ max.

Ambient temperature of the soldered surface of PC

board. 100℃ max.

Preheating time

60s max.

Soldering temperature

260℃ max.

Continuous dipping time

5s max.2

Number of soldering

2times max.

8.  Other precautions

(1)Following the soldering process, do not try to clean the switch with a solvent or the like.

(2)Safeguard the switch assembly against flux penetration from its topside.

(3)90

Please have the products keep in close status and the storage time is 90 days guaranty after delivering the goods at most.


  • Previous:
  • Next:

  • Write your message here and send it to us